Use este identificador para citar ou linkar para este item: http://repo.saocamilo-sp.br:8080/jspui/handle/123456789/1834
Título: Mid-term evaluation of istent inject® trabecular micro-bypass stent implantation with or without phacoemulsification: a retrospective study
Autor(es): Seixas, Regina Cele Silveira
Balbino, Marcos
Basile Neto, Alberto
Costa, Amanda de Alcantara Almeida
Jordão, Marcelo Lopes da Silva
Russ, Heloisa Helena Abil
Palavras-chave: Glaucoma
Terapêutica
Glaucoma - cirurgia
Catarata - cirurgia
Data do documento: 2020
Editor: Dove Medical Press Ltd
Citação: Seixas, Regina Cele Silveira. Mid-term evaluation of istent inject® trabecular micro-bypass stent implantation with or without phacoemulsification: a retrospective study. Clinical ophthalmology, v. 14, p. 4403–4413, 2020.
Resumo: Introduction: This study evaluated the 6-month performance and safety of micro-invasive glaucoma surgery (MIGS) with iStent inject either with or without cataract surgery. Material and Methods: Longitudinal retrospective study of 86 surgeries in 49 patients with inadequately controlled open-angle glaucoma (OAG) or ocular hypertension who underwent iStent inject trabecular micro-bypass implantation either alone (isolated group) or combined with cataract surgery (combined group). The two primary outcomes included an intraocular pressure (IOP) drop of ≥20% versus preoperative values (adequate drop) and IOP maintenance between 6 and 18 mmHg (adequate Range). For both outcomes, we determined “complete” and “qualified” success if patients did not require or did require glaucoma medications, respectively, at the end of follow-up. Safety outcomes included best-corrected visual acuity, adverse events, and secondary surgeries. Results: In the adequate drop analysis, 30.2% achieved “complete success,” and 37.2% achieved “qualified success.” For adequate range, 40.7% achieved “complete success” and 39.5% achieved “qualified success.” There was no difference in medication decrease (p=0.77) nor IOP reduction (p=0.46) between the isolated and combined groups. Safety was generally favorable and similar between groups, with mild transient adverse events that resulted in no sequelae.Discussion/Conclusion: iStent inject implantation either with or without cataract surgery was able to safely decrease IOP and medication requirements through 6 months after surgery
URI: http://repo.saocamilo-sp.br:8080/jspui/handle/123456789/1834
ISSN: 1177-5483
Aparece nas coleções:Artigos de Periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Marcos Balbino - Mid-term evaluation of istent.pdf3.27 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.